Power Supply Rejection Ratio

Use the Cleverscope Frequency Response Analyser to measure the Power Supply Rejection Ratio (PSRR) of a power supply with the CS1070 Power Amplifier.

It can manage up to 1A output current over a voltage range of -18V to +30V over a frequency range of DC - 52 MHz.  This is sufficient to directly measure many power supplies. If this is not enough, you can inject across a low value series resistor (eg 0.1 ohm). This video shows you how to connect up a CS328A-FRA and CS1070 to measure the PSRR of an LTC3589 over the frequency range 200 Hz - 10 MHz.

More from this section

Family of Curves

Family of Curves

This video shows you how to collect a family of Gain/Phase plots for a TI 5V 2.5A power supply, as the load current is varied from 2.5A to 1A and then 0.5A. > Read more

BNC Fixture Calibration

In addition we can compensate for the open circuit capacitance of the fixture. This video shows you how to simply calibrate a fixture, and then shows you the results with three 0603 SMT capacitors.... > Read more

×